GF Signet 3-2630.398 Chlorine Sensor Maintenance Kit

$465.00

Maintain GF Signet Type 2630 free chlorine sensors with kit 3-2630.398, including electrolyte, PTFE membranes, silicone bands and polishing paper.

SKU: 3-2630.398 Category: Brand:

Description

Manufacturer Part Number: 3-2630.398
GF Product Code: 159 310 166
Product Type: Free Chlorine Sensor Maintenance Kit
Compatibility: GF Signet Type 2630 Amperometric Free Chlorine Electrodes

Product Description

The GF Signet 3-2630.398 Free Chlorine Sensor Maintenance Kit provides the essential replacement components needed to service and recondition GF Signet Type 2630 amperometric free chlorine electrodes.

Designed for routine sensor maintenance, the kit includes replacement electrolyte, PTFE membranes, silicone bands, and polishing papers. These components help restore proper sensor response after normal membrane wear, electrolyte depletion, contamination, or extended service.

Regular maintenance of the chlorine electrode helps support stable, accurate free-chlorine measurements in drinking-water treatment, water distribution, cooling-water systems, food and beverage facilities, swimming pools, water parks, and other clean-water disinfection applications.

Kit Contents

Each GF Signet 3-2630.398 maintenance kit includes:

  • Two free-chlorine electrolyte supplies
  • Two replacement PTFE membranes
  • Two replacement silicone bands
  • Electrode polishing papers

Compatible GF Signet Sensors

The 3-2630.398 maintenance kit is designed for the following Type 2630 free chlorine electrodes:

  • 3-2630-1: 0.02–2 ppm free chlorine
  • 3-2630-2: 0.05–5 ppm free chlorine
  • 3-2630-3: 0.1–20 ppm free chlorine

This kit is intended for free chlorine sensors only. For the GF Signet 3-2632-1 chlorine dioxide electrode, use the dedicated 3-2632.398 Chlorine Dioxide Sensor Maintenance Kit.

Key Features and Benefits

  • Complete maintenance kit for GF Signet 2630 chlorine electrodes
  • Supports all three Type 2630 free-chlorine measurement ranges
  • Includes two sets of primary service components
  • Replacement PTFE membranes help restore proper chlorine diffusion
  • Fresh electrolyte supports reliable amperometric measurement
  • Silicone bands provide the correct replacement sealing components
  • Polishing papers allow proper reconditioning of the gold working electrode
  • Helps extend usable sensor life
  • Supports preventative maintenance programs
  • Convenient alternative to purchasing service components separately
  • Genuine GF Signet replacement components ensure proper compatibility

Typical Applications

The GF Signet 3-2630.398 maintenance kit supports chlorine sensors used in:

  • Drinking-water treatment
  • Municipal water distribution
  • Groundwater treatment
  • Surface-water treatment
  • Residual chlorine monitoring
  • Cooling-water and HVAC systems
  • Food and beverage processing
  • Swimming pools
  • Water parks
  • Industrial water-treatment systems
  • Clean-water disinfection processes

Sensor Maintenance

Maintenance may be required when the chlorine sensor cannot be calibrated, produces an unstable output, responds slowly, or develops a measurement difference compared with a DPD reference test.

During service, technicians can use the supplied polishing papers to recondition the sensor’s gold working electrode. The electrolyte and PTFE membrane can then be replaced according to the GF Signet Type 2630 operating instructions.

After replacing a membrane, the electrode must be conditioned in flowing chlorinated water and recalibrated before being returned to normal service. GF recommends using an appropriate DPD colorimetric test method for calibration verification.

Important Handling Information

Avoid touching the sensor’s gold electrode tip or the white surface of the PTFE membrane. Oils, dirt, scratches, or other contamination may affect sensor performance.

Always use appropriate gloves and eye protection when handling electrolyte. Do not use detergents, solvents, or surface-tension-reducing chemicals to clean the membrane. Installation and maintenance should be completed according to GF’s operating instructions.

Product Specifications

SpecificationDescription
ManufacturerGF Signet
Manufacturer Part Number3-2630.398
GF Product Code159 310 166
Product TypeChlorine sensor maintenance kit
Chlorine TypeFree chlorine
Compatible Sensor FamilyGF Signet Type 2630
Compatible Models3-2630-1, 3-2630-2 and 3-2630-3
Electrolyte SuppliesTwo
Replacement MembranesTwo
Membrane MaterialPTFE
Silicone BandsTwo
Polishing PapersIncluded
Sensor IncludedNo
Chlorine Dioxide CompatibilityNo—use kit 3-2632.398

Why Choose the GF Signet 3-2630.398?

The GF Signet 3-2630.398 combines the primary consumable and reconditioning components for Type 2630 free chlorine electrodes into one convenient service kit. Keeping a maintenance kit available helps reduce sensor downtime and allows technicians to address membrane damage, electrolyte loss, contamination, or declining sensor response without replacing the entire electrode.

Additional information

Weight1.75 lbs
Dimensions10 × 4 × 4 in