Signet Integral Conductivity Sensor, 4-20 mA Output Signal, SENSOR ELECTRONICS ONLY – NO SENSOR ELECTRODE

$650.00

Description

GF+ Signet 3-2850-52 Conductivity/Resistivity Monitor

Features

  • Integral mount systems for quick and easy installation
  • Compact design for maximum installation flexibility
  • Digital interface or two-wire 4 to 20 mA output
  • EasyCal with automatic test solution recognition
  • Dual channel unit available for low cost installation with Signet 8900 Multi-Parameter Controller
  • For use with ALL Signet conductivity electrodes

The GF Signet 2850 conductivity/resistivity sensor electronics are available in various configurations for maximum installation flexibility. The universal mount version of the GF Signet 2850 conductivity/resistivity sensor is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard GF Signet conductivity/resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. The GF Signet 2850 conductivity/resistivity sensor is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants.

GF Signet 2850 conductivity/resistivity sensors are available with a choice of two outputs, digital or 4 to 20 mA. The digital (S3L) output version of the GF Signet 2850 conductivity/resistivity sensor allows for up to six sensor inputs directly into the Signet 8900 Multi-Parameter Controller. The two-wire 4 to 20mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and is field selectable by the user.

The GF Signet 2850 conductivity/resistivity sensor is built with NEMA 4X/IP 65 enclosures, which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature of the GF Signet 2850 conductivity/resistivity sensor that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.

Additional information

Weight5 lbs
Dimensions6 × 4 × 4 in
Manufacturers Part No.

3-2850-52

Connection Type

3/4" FNPT

Input Voltage

12-24 VDC

Enclosure Rating

NEMA 4X / IP65

Code

159 001 399

Signal Type

4-20 mA

Electrical Connection Type

Blind Junction Box